MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-Nagel Macherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel image Macherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagel Macherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagel Macherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products

Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.5mm O.D.

Designed for separation of components according to boiling points. Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.5mm O.D. are non-polar phase columns with 100% dimethylpolysiloxane for use in gas chromatography. Available in a range of lengths and film thicknesses. Capillary column OPTIMA-1 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m,

Macherey-Nagel™ Potassium Iodide Starch Qualitative Test Paper

Allows the quick and easy detection of strong oxidizers such as nitrite and free chlorine. Macherey-Nagel™ Potassium Iodide Starch Qualitative Test Paper is also used to control diazotization reactions. Potassium iodide starch paper is available in two formats: 5m reel or 70 x 20mm test strips. X200 Test papier potassium iodide

Macherey-Nagel™ Aquadur™ teststrips

Bepaal de  waterhardheid snel, eenvoudig en betrouwbaar. De AquadurTM-teststrips bieden een gemakkelijke procedure met indopen en aflezen. Dankzij de duidelijke kleurverandering van groen naar rood zijn betrouwbare resultaten binnen seconden gegarandeerd.  Aquadur teststr.0-5-10-15-20

Macherey-Nagel™ Visocolor™ ECO titrimetrische testkit voor hardheid (totaal)

Provides titrimetric determination of total hardness. Macherey Nagel™ Visocolor™ Eco Hardness (Total) Test Kits are packed in an environmentally friendly box and contain easy to understand instructions in 6 languages.
Testkit Visoc.Eco totale hardh

Macherey Nagel Nanocolor Tube Test

Fast, easy-to-use, bar-coded, predosed test tubes for testing a variety of water and wastewater analysis parameters. NANOCOLOR TOTAAL STIKSTOF 22

Macherey-Nagel™ Visocolor™ ECO Test Kit Refill Pack

Replace consumed chemicals from test kits. Macherey-Nagel™ Visocolor™ ECO Test Kit Refill Packs are business-priced reagent sets used with ECO test kits. The kits use precisely-dosed single reagents, and results are evaluated visually with high-quality color comparison cards. Navulverpakking visocolor pH

Macherey-Nagel™ Quantofix™-peroxide 100 semi-kwantitatieve teststroken

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 100 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Quantofix M&N waterstofperoxid

Macherey-Nagel™ Quantofix™ semi-kwantitatieve teststroken ammoniak

Allows for the quick and easy determination of ammonium in solutions. Macherey Nagel™ Quantofix™ Ammonium Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents. X100 Quantofix M&N amm. bep.100

Macherey-Nagel™ Navulling pH-papier

Provides optimal quality and reliable readings. Macherey Nagel™ pH Indicator Paper Refills are supplied in plastic reels that ensure long-term stability and protection against many external influences. X3 Navulrol PH 1-11

Macherey-Nagel™ TLC-kamer voor simultane ontwikkeling

Ontwikkel meerdere TLC-platen tegelijk. TLC-kamers voor simultane ontwikkeling  worden geleverd met een keuze aan ruimte voor 2 of 5 platen. TLC-Separation-Chamber for 2 simultaneous separations, 10 x 10 cm plates

Macherey-Nagel™ Chromabond™ Leur Fitting

X12 CHROMABOND Luer fitting with lid male for Vacuum manifold

Macherey-Nagel™ Quantofix™-peroxide 25 semi-kwantitatieve teststroken

Ideal to test low levels of peroxide in solutions.  Macherey Nagel™ Quantofix™ Peroxide 25 Semi-quantitative Test Strips use an easy dip-and-read procedure and provide reliable results within 15 seconds. X100 Quantofix Perox 25:0-0,5-2-5-10-25 mg/l H2O2

Macherey-Nagel™ Chromabond™ C18 Polypropylene SPE Column

X20 CHROMABOND columns C18 volume: 45 mL, contentof sorbent: 5000 mg material: PP

Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID

Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions. Capillary column PERMABOND CW 20 M ID: 0.53 mm, film thickness: 1.0 µm length: 25 m

Macherey-Nagel™ Nucleodur™ C18 analytische EC-standaardkolom

Use EC standard columns for analytical HPLC (High Performance Liquid Chromatography). Nucleodur™ C18 Analytical EC Standard Columns come in a wide variety of lengths and internal diameters. EC HPLC column EC 125/3 NUCLEODUR C18 Pyramid, 5 µm length: 125 mm, ID: 3 mm

Macherey-Nagel™ Nucleosil™ CN/CN-RP 100-5 CN HPLC Column

EC HPLC column EC 250/4 NUCLEOSIL 100-5 CN Length: 250 mm, ID: 4 mm

Macherey-Nagel™ NUCLEODUR™ C18 Gravity HPLC Column, 1.8μm Particle Size

Ideal for ultra-fast HPLC separation of ketones. Macherey-Nagel™ NUCLEODUR™ C18 Gravity HPLC Column, 1.8μm Particle Size are analytical EC columns with high purity silica phase for HPLC. The columns are available in a variety of diameters and lengths. EC HPLC column EC 50/3 NUCLEODUR C18 Gravity, 3 µm length: 50 mm, ID: 3 mm

Macherey-Nagel™ Polygram CEL 300 PEI/UV254 Polyester Sheets

X25 POLYGRAM-Fertigfolien CEL 300 PEI/UV254 Format:

Macherey Nagel pH Indicator Papers, Refill

The longstanding, appreciated standard for many pH testing applications. X3 Refill pack pH 9,0-13,0 in pH stappen

Macherey-Nagel™ Chromabond™ C18 Polypropylene Column

X50 CHROMABOND Columns C18 volume: 3 mL, content of sorbent: 500 mg material: PP

Macherey-Nagel™ Glazen plaat, adamant UV254

Increase separation efficiency and maximize resolution during TLC (thin-layer chromatography). Adamant™ Unmodified Standard Silica Layers for TLC, UV254, are available on glass plates with an optimized binder system and UV indicator. X25DC-platen Adamant UV 254 Format: 20x20 cm

Macherey-Nagel™ Optima™ 5 High Performance GC Capillary Column

Capillary column OPTIMA-5 ID: 0.25 mm, film thickness: 0.5 µm length: 25 m,

Macherey-Nagel™ Nucleosil™ SB Quaternary Ammonium Ion Exchange HPLC Column, 10 μm, 4.6 mm x 250 mm

Column Format: Analytical Column; Carbon Load: 10%; Pore Size: 100 Å; Column Phase: Ion Exchange EC HPLC column EC 250/4.6 NUCLEOSIL 100-10 SB length: 250 mm, ID: 4.6 mm

Macherey-Nagel™ Nucleodur™ 100-5 CN Analytical EC Standard Column

EC HPLC column EC 125/4.6 NUCLEODUR 100-5 CN-RP length: 125 mm, ID: 4.6 mm

Macherey-Nagel™ Optima™ 17 GC Capillary Column

Capillary column OPTIMA-17 ID: 0.25 mm, film thickness: 0.15 µm length: 25 m,

Macherey-Nagel™ Nucleodur™ C18 Isis HPLC Column

EC HPLC column EC 75/2 NUCLEODUR C18 Isis, 1.8 µmlength: 75 mm, ID: 2 mm

Macherey-Nagel™ Polypropylene Reservoir Column

X10 CHROMABOND reservoir column volume: 70 mL, material: PP with adaptor for 15, 45, 70 mL columns

Macherey-Nagel™ N20 aluminium sluitingen

Seal vials with securely with a variety of crimp closures. Machenery-Nagel™ N20 aluminum closures come with a broad variety of cap types and septum materials. X100 Aluminium crimp caps N20 B/oA w. centre hole

Macherey-Nagel™ PEEK Standard Capillaries

PEEK Standardkapillaren AD: 1/16', ID: 0,13 mm,Länge: 1m

  spinner