missing translation for 'onlineSavingsMsg'
Learn More

Tantalum(V) chloride, anhydrous, Puratronic™, 99.995% (metals basis), Thermo Scientific Chemicals

75.78 € - 491.45 €

Chemical Identifiers

CAS 7721-01-9
Molecular Formula Cl5Ta
Molecular Weight (g/mol) 358.20
MDL Number MFCD00011253
InChI Key OEIMLTQPLAGXMX-UHFFFAOYSA-I
Synonym Tantalum pentachloride
IUPAC Name tantalum(5+) pentachloride
SMILES [Cl-].[Cl-].[Cl-].[Cl-].[Cl-].[Ta+5]
View More Specs

Products 3
Product Code Brand Quantity Price Quantity & Availability  
Product Code Brand Quantity Price Quantity & Availability  
11310348
View Documents
Thermo Scientific Alfa Aesar
043731.06
5 g
75.78 €
5g
Please to purchase this item. Need a web account? Register with us today!
11300348
View Documents
Thermo Scientific Alfa Aesar
043731.14
25 g
202.01 €
25g
Please to purchase this item. Need a web account? Register with us today!
11320348
View Documents
Thermo Scientific Alfa Aesar
043731.22
100 g
491.45 €
100g
Please to purchase this item. Need a web account? Register with us today!
Description

Description

This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.

  • Ampouled under argon
Specifications

Chemical Identifiers

7721-01-9
358.20
OEIMLTQPLAGXMX-UHFFFAOYSA-I
tantalum(5+) pentachloride
Cl5Ta
MFCD00011253
Tantalum pentachloride
[Cl-].[Cl-].[Cl-].[Cl-].[Cl-].[Ta+5]

Specifications

242°C
7721-01-9
Powder
MFCD00011253
14,9054
OEIMLTQPLAGXMX-UHFFFAOYSA-I
tantalum(5+) pentachloride
358.21
Puratronic™
Ampule
3.68 g/mL
Tantalum (V) chloride, Anhydrous
216°C
White to Yellow
Cl5Ta
UN3260
Tantalum pentachloride
[Cl-].[Cl-].[Cl-].[Cl-].[Cl-].[Ta+5]
358.20
99.995%
Acidic
Moisture sensitive
(metals basis)
Videos
Safety and Handling

Safety and Handling

GHS H Statement
H314-H318-H302
Causes severe skin burns and eye damage.
Causes serious eye damage.
Harmful if swallowed.

P260-P264b-P270-P271-P280-P303+P361+P353-P304+P340-P305+P351+P338-P310-P330-P331-P363-P501c

H302-H314-H335

missing translation for 'dotInformation' : Hazard Class: 8; Packaging Group: II

missing translation for 'einecsNumber' : 231-755-6

missing translation for 'rtecsNumber' : WW5600000

missing translation for 'tsca' : Yes

missing translation for 'storageNote' :

  • Ampouled under argon

Recommended Storage : Ambient temperatures; Store under Argon

Product Identifier
  • Tantalum(V) chloride, anhydrous, Puratronic

Signal Word
  • Danger

Hazard Category
  • Acute toxicity Category 4
  • Skin corrosion/irritation Category 1 B

Hazard Statement
  • H302-Harmful if swallowed.
  • H314-Causes severe skin burns and eye damage.

Precautionary Statement
  • P260-Do not breathe dust/fume/gas/mist/vapours/spray.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P330+P331-IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P304+P340-IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P363-Wash contaminated clothing before reuse.
  • P405-Store locked up.
  • P501-Dispose of contents/container to .

SDS
Documents

Documents

Product Certifications

RUO – Research Use Only

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.