missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Orion™ Sodium Electrodes

Measure sodium in aqueous solution quickly, accurately and economically with these sodium electrodes.

Brand:  Thermo Scientific™ 8411BN

414.80 EUR valid until 2024-12-31
Use promo code "21658" to get your promotional price.



 View more versions of this product

Product Code. 10451213

  • 502.50 € / Each
In Stock
to see stock.
Explore more special offers
Add to basket
This item is not returnable. View return policy

Description

Description

Measure sodium in aqueous solutions quickly, accurately and economically with Thermo Scientific™ Orion™ Sodium Electrodes. A unique redox internal system with a Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, and greater stability and accuracy than conventional sodium electrodes.

8611BNWP is a combination electrode with a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap.

8411BN is a half cell sensor that requires either ROSS reference electrode 800300 or ROSS Ultra reference electrode 800500U to function.

The sodium electrode is commonly used to measure samples such as food, beverages and animal feed.

Features
8611BNWP is a combination electrode with a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. 8411BN is a half cell sensor that requires ROSS reference electrode, Cat. No. 800300 or the ROSS Ultra reference electrode, Cat. No. 800500U to function.
 
Solutions required
Standards
941706     0.1 M NaCl sodium standard solution, 475 mL bottle
841108     1000 ppm sodium standard solution, 475 mL bottle
941107     100 ppm sodium standard solution, 475 mL bottle
941105     10 ppm sodium standard solution, 475 mL bottle
 
Known standards addition
841109     Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
650700     Sodium known addition standard, 1 M with ISA, 475 mL bottle
 
ISA
841111     Sodium ISA, 475 mL bottle
 
Electrode fill solution
900010     ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles. 
                For regular sodium measurements (> 10-5 M or 0.2 ppm)
900012     ROSS sodium and reference electrode  filling solution, 5 x 50 mL bottles. 
                For low-level sodium measurements (< 10-5M or 0.2 ppm)
 
841101     Sodium electrode storage solution, 475 mL bottle
 
Recondition solution 
841113     Sodium electrode reconditioning solution, 475 mL bottle
 
Items included with
841113     Sodium electrode reconditioning solution, 475 mL bottle
841111     Sodium ISA, 475 mL bottle
841109     Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
841108     1000 ppm sodium standard solution, 475 mL bottle
900010     ROSS sodium and reference electrode. 60mL 1 bottle
841101     Sodium electrode storage solution, 475 mL bottle
 
Warranty period
12 months from date of purchase by Buyer or 18 months from date of shipment from Seller, whichever is earlier.
TRUSTED_SUSTAINABILITY
Specifications

Specifications

Measures sodium in aqueous solution quickly, accurately, and economically; Unique redox internal system with ROSS™ electrode provides faster response, greater stability and accuracy than conventional sodium electrodes
ROSS half-cell BNC Orion sodium electrode
13 mm
800300 or 800500U
39.3 in.
1 M
Saturated to 10-6 M, saturated to 0.02ppm
ISE Meters
  • 1 x 10-6 M to saturated
  • 0.02 ppm to saturated
No
BNC
0.47 in
900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
4.72 in
120 mm
Glass Body
32 to 176°F
0°C to 100°C
Sodium Half-Cell Ion Selective Electrode
Product Suggestions

Product Suggestions

Videos
Safety and Handling

Safety and Handling

Signal Word
  • Warning

Hazard Category
  • LONG-TERM AQUATIC HAZARD Chronic 3
  • Serious eye damage/eye irritation Category 2
  • LONG-TERM AQUATIC HAZARD Chronic 3
  • Skin corrosion/irritation Category 2
  • Skin sensitiser Category 1
  • Serious eye damage/eye irritation Category 2

Hazard Statement
  • H317-May cause an allergic skin reaction.
  • H315-Causes skin irritation.,Causes skin irritation.
  • H319-Causes serious eye irritation.,Causes serious eye irritation.
  • H412-Harmful to aquatic life with long lasting effects.,Harmful to aquatic life with long lasting effects.
  • H302-Harmful if swallowed.

Precautionary Statement
  • P264-Wash thoroughly after handling.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.,Wear protective gloves/protective clothing/eye protection/face protection.
  • P302+P352-IF ON SKIN: Wash with plenty of water/.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.,IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P332+P313-If skin irritation occurs: Get medical advice/attention.
  • P337+P313-If eye irritation persists: Get medical advice/attention.
  • P362-Take off contaminated clothing.
  • P403-Store in a well-ventilated place.
  • P501-Dispose of contents/container to .

SDS
Documents

Documents

Certificates
View accessory products
Special Offers

Special Offers